Companies › Beckman Coulter Inc.

Beckman Coulter Inc.: PFAS in products reported to Minnesota

Beckman Coulter Inc. has 653 published disclosure rows in PRISM, in 1 report, covering 1 brand, 14 brand/model combinations, 11 component types and 11 PFAS entries. Most recent publication: Sep 24, 2026.

Each row = one PFAS in one component of one product as reported by the manufacturer. Concentrations are reported as ranges.

Reports

Report IDRowsSubmitted (UTC)Published (UTC)
MN-HYNCO196532026-08-102026-09-24

PFAS reported

PFAS function

FunctionRows
Chemical/Fuel/Oil Resistance97
Barrier96
Lubricating agent78
Other67
Surface modifier59
Anti-adhesive/cohesive50
Insulators48
Solids separation (precipitating) agent, not otherwise specified29
Waterproofing agent29
Sealant22
Flame retardant20
Viscosity modifiers20
Corrosion inhibitor19
Dielectric9
Stabilizing agent5
Surfactant5

Concentration range

RangeRows
90 to 100%521
10,000 ppm to <150,000 ppm (15%)59
100 ppm to <1,000 ppm (0.1%)42
300,000 to <600,000 ppm (60%)27
1,000 ppm to <10,000 ppm (1%)4

Components containing PFAS

ComponentRows
Seal177
Plastic mechanical component117
Filter87
Tubing61
Lubricant57
Anti-drip fire agent40
Sensor Housing38
Electrical Wire27
Chemical Resistant Wetted Components20
Rigid Fluid Component19
Reagent10

Brands

Beckman Coulter 653

Example records

One example row per component type (up to 25). Full record-level data: PRISM, or the Apify actor with {"manufacturers": ["Beckman Coulter Inc."]}.

BrandModelComponentPFASFunctionRange
Beckman CoulterFlow CytometrySealEthene, 1,1,2,2-tetrafluoro-, homopolymer (9002-84-0)Sealant90 to 100%
Beckman CoulterFlow CytometryPlastic mechanical componentEthene, 1,1,2,2-tetrafluoro-, homopolymer (9002-84-0)Lubricating agent90 to 100%
Beckman CoulterFlow CytometryFilterpoly(1,1-difluoroethylene) (PVDF) (24937-79-9)Solids separation (precipitating) agent, not otherwise specified90 to 100%
Beckman CoulterFlow CytometryTubingEthene, 1,1,2,2-tetrafluoro-, homopolymer (9002-84-0)Insulators90 to 100%
Beckman CoulterFlow CytometryLubricantperfluoropolyether (PFPE 1) (60164-51-4)Lubricating agent10,000 ppm to <150,000 ppm (15%)
Beckman CoulterFlow CytometryAnti-drip fire agentEthene, 1,1,2,2-tetrafluoro-, homopolymer (9002-84-0)Flame retardant100 ppm to <1,000 ppm (0.1%)
Beckman CoulterFlow CytometrySensor Housingpoly(1,1-difluoroethylene) (PVDF) (24937-79-9)Chemical/Fuel/Oil Resistance90 to 100%
Beckman CoulterParticle Counter AnalyzersElectrical Wire1-Propene, 1,1,2,3,3,3-hexafluoro-, polymer with 1,1,2,2-tetrafluoroethene (25067-11-2)Insulators300,000 to <600,000 ppm (60%)
Beckman CoulterFlow CytometryChemical Resistant Wetted ComponentsEthene, 1,1,2,2-tetrafluoro-, homopolymer (9002-84-0)Chemical/Fuel/Oil Resistance90 to 100%
Beckman CoulterFlow CytometryRigid Fluid Componentpoly(1,1-difluoroethylene) (PVDF) (24937-79-9)Chemical/Fuel/Oil Resistance90 to 100%
Beckman CoulterLaboratory ReagentReagent2,2,3,3,4,4,5,5,6,6,7,7,8,8,8-pentadecafluorooctanoic acid (335-67-1)Surfactant1,000 ppm to <10,000 ppm (1%)

Get notified when new PFAS reports are published

Every week: which manufacturers' reports MPCA newly published in PRISM, notable chemicals and components, and changes to existing reports. Free. One email a week. Unsubscribe in one click.

Need the raw records or alerts?

The PFAS Product Disclosure Radar on Apify exports PRISM disclosures as JSON/CSV/Excel, filtered by brand, manufacturer, CAS number, component or PFAS function, and can run on a schedule to flag only new records. Track Beckman Coulter Inc. alone by setting the manufacturer filter. Pay per result (about $1 per 1,000 records).

Open the Apify actor →