Companies › AtriCure, Inc.
AtriCure, Inc.: PFAS in products reported to Minnesota
AtriCure, Inc. has 89 published disclosure rows in PRISM, in 1 report, covering 1 brand, 35 brand/model combinations, 49 component types and 1 PFAS entry. Most recent publication: Sep 29, 2026.
Each row = one PFAS in one component of one product as reported by the manufacturer. Concentrations are reported as ranges.
Reports
| Report ID | Rows | Submitted (UTC) | Published (UTC) |
|---|---|---|---|
| MN-89Q69X0 | 89 | 2026-08-20 | 2026-09-29 |
PFAS reported
| PFAS | Rows |
|---|---|
| Fluoropolymers | 89 |
PFAS function
| Function | Rows |
|---|---|
| Lubricating agent | 41 |
| Barrier | 40 |
| Insulators | 8 |
Concentration range
| Range | Rows |
|---|---|
| 90 to 100% | 43 |
| 600,000 to <900,000 ppm (90%) | 32 |
| 10,000 ppm to <150,000 ppm (15%) | 11 |
| 150,000 ppm to <300,000 ppm (30%) | 2 |
| Present but the amount or concentration range is unknown | 1 |
Components containing PFAS
| Component | Rows | |
|---|---|---|
| Thermocouple shrink tube | 10 | |
| Handle rail lubricant | 7 | |
| Plunger lubricant | 7 | |
| Distal jaw weldment lubricant | 4 | |
| Pivot Shaft Grease | 4 | |
| Shaft Shrink Tube | 4 | |
| Black LED Wire | 2 | |
| Distal insulator shrink tubing | 2 | |
| Electrode shrink tubing, distal jaw | 2 | |
| Electrode shrink tubing, proximal jaw | 2 | |
| End Effector Lubricant | 2 | |
| Inner RF Wire Shrink Tube | 2 | |
| Outer RF Wire Shrink Tube | 2 | |
| Pivot Shaft Lubricant | 2 | |
| Proximal insulator shrink tubing | 2 | |
| White LED Wire | 2 | |
| 13 French Dilator | 1 | |
| Articulating jaw weldment lubricant | 1 | |
| Balloon Protector Heat Shrink | 1 | |
| Cable Lubricant | 1 | |
| Cam weldment lubricant | 1 | |
| Distal jaw shrink tubing | 1 | |
| Distal ribbon cable insulator | 1 | |
| Drive bar lubricant | 1 | |
| Exhaust Hose Teflon Tape | 1 | |
| Filter Cartridge | 1 | |
| Gas Purifier Shell Housing | 1 | |
| Guidewire coils | 1 | |
| Inner end effector lubricant | 1 | |
| Jaw Lubricant | 1 |
+ 19 more component types
Brands
AtriCure 89
Example records
One example row per component type (up to 25). Full record-level data: PRISM, or the Apify actor with {"manufacturers": ["AtriCure, Inc."]}.
| Brand | Model | Component | PFAS | Function | Range |
|---|---|---|---|---|---|
| AtriCure | CRYO2 Probe | Thermocouple shrink tube | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | EML2 Clamp | Handle rail lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | EML2 Clamp | Plunger lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | EML2 Clamp | Distal jaw weldment lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | MID1 Dissector | Pivot Shaft Grease | Fluoropolymers | Lubricating agent | 600,000 to <900,000 ppm (90%) |
| AtriCure | MAX1 Pen | Shaft Shrink Tube | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | MID1 Dissector | Black LED Wire | Fluoropolymers | Insulators | 10,000 ppm to <150,000 ppm (15%) |
| AtriCure | EML2 Clamp | Distal insulator shrink tubing | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | OLL2 Clamp | Electrode shrink tubing, distal jaw | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | OLL2 Clamp | Electrode shrink tubing, proximal jaw | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | PRO2 Clip | End Effector Lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | OLH Clamp | Inner RF Wire Shrink Tube | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | OLH Clamp | Outer RF Wire Shrink Tube | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | MID1 Dissector | Pivot Shaft Lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | EML2 Clamp | Proximal insulator shrink tubing | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | MID1 Dissector | White LED Wire | Fluoropolymers | Insulators | 10,000 ppm to <150,000 ppm (15%) |
| AtriCure | SofTIP Guide Cannula | 13 French Dilator | Fluoropolymers | Barrier | 90 to 100% |
| AtriCure | EMH Clamp | Articulating jaw weldment lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | EndoCATH Occlusion Balloon Device | Balloon Protector Heat Shrink | Fluoropolymers | Barrier | 90 to 100% |
| AtriCure | PRO1 Clip | Cable Lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | EMH Clamp | Cam weldment lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | EMT1 Clamp | Distal jaw shrink tubing | Fluoropolymers | Barrier | 600,000 to <900,000 ppm (90%) |
| AtriCure | EMT1 Clamp | Distal ribbon cable insulator | Fluoropolymers | Insulators | 10,000 ppm to <150,000 ppm (15%) |
| AtriCure | EMH Clamp | Drive bar lubricant | Fluoropolymers | Lubricating agent | 90 to 100% |
| AtriCure | ACM Generator and Accessories | Exhaust Hose Teflon Tape | Fluoropolymers | Barrier | 90 to 100% |
Get notified when new PFAS reports are published
Every week: which manufacturers' reports MPCA newly published in PRISM, notable chemicals and components, and changes to existing reports. Free. One email a week. Unsubscribe in one click.
Need the raw records or alerts?
The PFAS Product Disclosure Radar on Apify exports PRISM disclosures as JSON/CSV/Excel, filtered by brand, manufacturer, CAS number, component or PFAS function, and can run on a schedule to flag only new records. Track AtriCure, Inc. alone by setting the manufacturer filter. Pay per result (about $1 per 1,000 records).